{"id":11473,"date":"2023-03-13T14:04:05","date_gmt":"2023-03-13T14:04:05","guid":{"rendered":"https:\/\/microtech.tools\/product\/tablet-micron-height-gauge-force-1-20n-industry-40\/"},"modified":"2026-05-18T14:37:19","modified_gmt":"2026-05-18T11:37:19","slug":"medidor-de-altura-2","status":"publish","type":"product","link":"https:\/\/microtech.tools\/es\/product\/medidor-de-altura-2\/","title":{"rendered":"DataMet Medidor de altura de tabletas Fuerza 1-20N Industria 4.0"},"content":{"rendered":"<p><iframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/v0_qXjk-jx0?si=OM0v7iF05Jk8afV7\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<div>\n<p class=\"\" data-start=\"2611\" data-end=\"2864\"><strong data-start=\"2611\" data-end=\"2864\">Calibre alt\u00edmetro computarizado microm\u00e9trico con control de fuerza de medici\u00f3n 1-20N, con transmisi\u00f3n de datos inal\u00e1mbrica y USB, adaptado a Industry 4.0, desarrollado y patentado por MICROTECH Kharkiv (Pat. US10184772, UA111194, UA112361, UA121681)<\/strong><\/p>\n<p class=\"\" data-start=\"2866\" data-end=\"3263\">El calibre alt\u00edmetro MICRON de MICROTECH est\u00e1 equipado con un m\u00f3dulo patentado de control de fuerza e-Force, que permite realizar mediciones con la fuerza necesaria en el rango de 1-20N. En el modo autom\u00e1tico e-Force, es posible guardar en la memoria o transmitir a la aplicaci\u00f3n los datos actuales al alcanzar la fuerza establecida, lo que mejora la precisi\u00f3n y automatiza el proceso de medici\u00f3n.<\/p>\n<p class=\"\" data-start=\"3265\" data-end=\"3472\">Los calibres alt\u00edmetros de precisi\u00f3n se fabrican con rangos de medici\u00f3n de 300, 500, 1000, 1500, 2000 mm (12, 20, 40, 60, 80 pulgadas) y una resoluci\u00f3n de 1 \u03bcm (0,001 mm) gracias al sistema de lectura suizo.<\/p>\n<p class=\"\" data-start=\"3474\" data-end=\"3563\">El sistema de medici\u00f3n computarizado del indicador MICS incluye las siguientes funciones:<\/p>\n<ul data-start=\"3565\" data-end=\"4870\">\n<li class=\"\" data-start=\"3565\" data-end=\"3645\">\n<p class=\"\" data-start=\"3567\" data-end=\"3645\">Memoria interna para 2000 valores con modo estad\u00edstico y sistema de carpetas<\/p>\n<\/li>\n<li class=\"\" data-start=\"3646\" data-end=\"3687\">\n<p class=\"\" data-start=\"3648\" data-end=\"3687\">Indicaci\u00f3n de l\u00edmites Go\/NoGo a color<\/p>\n<\/li>\n<li class=\"\" data-start=\"3688\" data-end=\"3718\">\n<p class=\"\" data-start=\"3690\" data-end=\"3718\">Funci\u00f3n de picos (Min\/Max)<\/p>\n<\/li>\n<li class=\"\" data-start=\"3719\" data-end=\"3773\">\n<p class=\"\" data-start=\"3721\" data-end=\"3773\">Temporizador (memorizaci\u00f3n o transmisi\u00f3n de datos)<\/p>\n<\/li>\n<li class=\"\" data-start=\"3774\" data-end=\"3818\">\n<p class=\"\" data-start=\"3776\" data-end=\"3818\">F\u00f3rmula \u2013 c\u00e1lculo del indicador Ax\u00b2+Bx+C<\/p>\n<\/li>\n<li class=\"\" data-start=\"3819\" data-end=\"3844\">\n<p class=\"\" data-start=\"3821\" data-end=\"3844\">Selecci\u00f3n mm\/pulgadas<\/p>\n<\/li>\n<li class=\"\" data-start=\"3845\" data-end=\"3883\">\n<p class=\"\" data-start=\"3847\" data-end=\"3883\">Compensaci\u00f3n manual de temperatura<\/p>\n<\/li>\n<li class=\"\" data-start=\"3884\" data-end=\"3928\">\n<p class=\"\" data-start=\"3886\" data-end=\"3928\">Compensaci\u00f3n lineal del error matem\u00e1tico<\/p>\n<\/li>\n<li class=\"\" data-start=\"3929\" data-end=\"3967\">\n<p class=\"\" data-start=\"3931\" data-end=\"3967\">Control de la fecha de calibraci\u00f3n<\/p>\n<\/li>\n<li class=\"\" data-start=\"3968\" data-end=\"4079\">\n<p class=\"\" data-start=\"3970\" data-end=\"4079\">Transmisi\u00f3n de datos inal\u00e1mbrica a dispositivos Windows, iOS, Android (aplicaci\u00f3n MICROTECH MDS \u2013 gratuita)<\/p>\n<\/li>\n<li class=\"\" data-start=\"4080\" data-end=\"4216\">\n<p class=\"\" data-start=\"4082\" data-end=\"4216\">Transmisi\u00f3n de datos v\u00eda USB HID a dispositivos Windows, MacOS, Linux, Android (modo teclado) con configuraci\u00f3n del formato de datos<\/p>\n<\/li>\n<li class=\"\" data-start=\"4217\" data-end=\"4335\">\n<p class=\"\" data-start=\"4219\" data-end=\"4335\">Transmisi\u00f3n inal\u00e1mbrica de datos HID (modo teclado) a cualquier sistema y aplicaci\u00f3n con configuraci\u00f3n del formato<\/p>\n<\/li>\n<li class=\"\" data-start=\"4336\" data-end=\"4397\">\n<p class=\"\" data-start=\"4338\" data-end=\"4397\">Bater\u00eda recargable Li-Pol con carga a trav\u00e9s de micro-USB<\/p>\n<\/li>\n<li class=\"\" data-start=\"4398\" data-end=\"4448\">\n<p class=\"\" data-start=\"4400\" data-end=\"4448\">Pantalla t\u00e1ctil a color Hi-Res de 2,4 pulgadas<\/p>\n<\/li>\n<li class=\"\" data-start=\"4449\" data-end=\"4511\">\n<p class=\"\" data-start=\"4451\" data-end=\"4511\">Indicaci\u00f3n del estado de conexi\u00f3n en la pantalla principal<\/p>\n<\/li>\n<li class=\"\" data-start=\"4512\" data-end=\"4551\">\n<p class=\"\" data-start=\"4514\" data-end=\"4551\">Modo gr\u00e1fico en l\u00ednea (tiempo real)<\/p>\n<\/li>\n<li class=\"\" data-start=\"4552\" data-end=\"4590\">\n<p class=\"\" data-start=\"4554\" data-end=\"4590\">Escala anal\u00f3gica a color ajustable<\/p>\n<\/li>\n<li class=\"\" data-start=\"4591\" data-end=\"4654\">\n<p class=\"\" data-start=\"4593\" data-end=\"4654\">Conexi\u00f3n HUB (dispositivos inal\u00e1mbricos externos MICROTECH)<\/p>\n<\/li>\n<li class=\"\" data-start=\"4655\" data-end=\"4721\">\n<p class=\"\" data-start=\"4657\" data-end=\"4721\">Conexi\u00f3n 2D (dispositivos externos con indicaci\u00f3n inal\u00e1mbrica)<\/p>\n<\/li>\n<li class=\"\" data-start=\"4722\" data-end=\"4818\">\n<p class=\"\" data-start=\"4724\" data-end=\"4818\">Conexi\u00f3n de sonda de medici\u00f3n (indicador externo o indicador de palanca) con modo autom\u00e1tico<\/p>\n<\/li>\n<li class=\"\" data-start=\"4819\" data-end=\"4870\">\n<p class=\"\" data-start=\"4821\" data-end=\"4870\">Posibilidad de actualizaci\u00f3n del firmware v\u00eda USB<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4872\" data-end=\"5050\">Todos los calibres alt\u00edmetros de MICROTECH tienen superficies de medici\u00f3n acabadas a mano (Ra&lt;0,32) y pasan control metrol\u00f3gico en un laboratorio acreditado seg\u00fan ISO 17025 ILAC.<\/p>\n<p class=\"\" data-start=\"5052\" data-end=\"5169\"><strong data-start=\"5052\" data-end=\"5169\">A solicitud del cliente, es posible a\u00f1adir funciones y f\u00f3rmulas adicionales seg\u00fan los requisitos de Industry 4.0.<\/strong><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h4>Medidor de altura informatizados en tableta con control de medici\u00f3n e-Force 1-20N con transferencia de datos inal\u00e1mbrica y USB adoptada para Industria 4.0 (Pat. US10184772)<\/h4>\n","protected":false},"featured_media":20238,"template":"","meta":{"_acf_changed":false},"product_brand":[6886],"product_cat":[3345],"product_tag":[],"class_list":["post-11473","product","type-product","status-publish","has-post-thumbnail","product_brand-microtech","product_cat-medidor-de-altura","pa_battery-li_pol","pa_dataoutput-usbhid","pa_dataoutput-wireless","pa_dataoutput-wirelesshid","pa_indication-computerized2_4","pa_measrange-1000mm40inch","pa_measrange-1500mm60inch","pa_measrange-2000mm80inch","pa_measrange-300mm12inch","pa_measrange-500mm20inch","pa_resolution_mm-0-0005","first","instock","shipping-taxable","purchasable","product-type-variable"],"acf":[],"_links":{"self":[{"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/product\/11473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/media\/20238"}],"wp:attachment":[{"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/media?parent=11473"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/product_brand?post=11473"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/product_cat?post=11473"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/microtech.tools\/es\/wp-json\/wp\/v2\/product_tag?post=11473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}